Operating instructions

Sub-menu Times
Delay betw een pedal level 1 (low ering the clamping foot) and
sew ing start (t1)
This time is only relevant with quick start via pedal or hand switch
(optional).
The menu is item is only displayed when the monitoring switch for the
clamping foot is not connected.
Input: 50 255 ms
Turn-on delay for the thread w iper magnet (t2)
This menu item will only be displayed if the “electric thread wiper”
option is activated in the “ Configuration” menu.
Input: 30 100 ms
Delay thread w iper magnet off - clamping foot magnet on (t3)
The delay between the switching off of the thread wiper magnet and
the switching on of the clamping foot magnet.
This menu item will only be displayed if the option “electric thread
wiper” is activated in the “ Configuration” menu.
Input: 0 255 ms
Delay betw een clamping foot magnet on reference run (t4)
The delay between the switching on of the clamping foot magnet and
the referencing of the step motors.
The menu is item is only displayed when the monitoring switch for the
clamping foot is not connected.
Input: 0 255 ms
Activation time for the pow er saving mode (t5)
Delay time after activation of any control element (control panel, pedal,
hand switch) until the power saving mode is activated.
Input: 0 60 min 0 =Power saving mode deactivated
44