Operating instructions

Referencing
The referencing mode of the step motor after the sewing process c an
be configured in this menu item.
Input: 0 = no referencing
1 = referencing each time
2 10 = referencing after each second to tenth
sewing step
Closed thread clamp angle
Setting the angle for closing the thread clamp.
Input: 100 ° 240°
Opened thread clamp angle
Setting the angle for opening the thread clamp.
Input: Closed thread clamp ... 355°
Opened thread tension angle
Setting the angle for opening the thread tension in the last stitch.
Input: 200° 355°
The thread tension is opened before the thread-cut position is reached.
Thus only the mechanical pre-tensioner is active during the cutting
process.
All angles are specified in relation to the reference position of the
sewing motor.
38