Operating instructions
8.6.2 Programming mode
Under this menu item, the parameters for programming of seam
patterns are arranged.
With the help of these parameters, the shape, length, width and speed
of the seam pattern are specified.
–
Turn on the main switch.
The control unit is initialized.
The main menu appears.
–
Press function key “P” on the main menu.
The display changes over to the menu of the programming mode.
–
Select the desired parameter with the “ñ” and “ò”keys.The
symbol of the selected parameter is displayed white on black.
–
Alter the selected parameter as described in chapter 8.3.
Number of seam pattern
The number of the seam pattern to be created or altered is selected
using this parameter.
When preparing a new program, an asterisk (*) is indicated before the
number.
Input: 51 90
–
Select the desired seam pattern program with the “ñ” and “ò”
keys.
–
Press the “OK” key.
The program is activated.
Basic seam pattern
Using this parameter, a standard seam pattern can be selected on the
basis of which the new seam pattern is to be created.
Input: 1 50 or
91 99 if available
Sew ing speed
Using this parameter, the desired sewing speed can be adjusted.
Input: 0 – 2700 [rpm]
26
:51
:1
: 2700
:25
: 16.0/ 2.0
: 0.0/ 0.0
:42
:On