7.8 Replacing the needle
Caution Risk of Injury !
Turnthemainswitchoff.
Change the needle only when the automatic bartacker is switched off.
Loosen screw 1.
Push in the new needle until it reaches the limit stop in the hole for
the needle bar 2.
CAUTION !
The hollow groove 3 of the needle must point to the hook.
Tighten screw 1.
CAUTION !
After the changeover to another needle size, the distance between
hook and needle has to be corrected (see service instructions).