Operating instructions
12. Clamping feet
Clamping foot no.
Max. tack size
I(X/Y) [mm]
Rectangular
inner frame
Default standard
seam pattern
number
Valid standard
seam pattern
Description
Comment
1 19.0 x 3.5 yes 1 all Cross tack Standard configuration
Cl. 511-211
2 20.0 x 4.1 yes 1 all Cross tack Standard configuration
Cl. 511-213
3 26.0 x 4.0 yes 4 all large c ross-tack Optional
4 9.0 x 3.5 yes 2 all Small cross-tack Optional
5 4.6 x 20.0 yes 23 all Longitudinal tack Optional
6 18.0 x 11.0 yes 47 all Small-field clamping foot Optional
7 40.0 x 20.0 yes 48 all Large-field clamping foot Optional
8 8 .5 x 3.6 yes 11 all Contraction clamp Standard configuration
Cl. 511-212
9 14.0 x 14.0 no 31 31, 32, 33, 34 Circle Optional
10 11.0 x 8.0 no 35 35, 36 D-clamping foot, s imple Optional
11 8.6 x 11.6 no 41 41, 42, 43, 44 Double-D clamping foot Optional
sideways
12 11.6 x 7.5 no 37 37, 38, 39, 40 Double-D clamping foot Optional
Longitudinal
13 12.9 x 11.2 no 49 49, 50 Double-tri clamping foot Optional
sideways
14 16.0 x 2.6 yes 1 all Cross tack Optional
15 - yes - - Clamping blank Optional*
16 8.6 x 13.6 no 41 41, 42, 43, 44 Double-D clamping foot Optional
Sideways, large
* Clamping foot cannot be selected. Specify free contour size
Note:
For those clamping feet which have a centre bar (e.g., the double-D
clamping foot on the side or in-house home-made feet), the clamping
foot lift must be decreased so that the needle does not collide with the
centre bar during the referencing movement (refer to the servicing
instructions in Chapter 6.4).
1
97