Operation Manual

Compressed air maintenance unit (optional equipment)
If the special sewing machine is equipped with the compressed air maintenance unit
WE-6, the maintenance work listed in the table below is also to be conducted.
Required Remarks Operating
maintenance work hours
Compressed air
maintenance unit
- Check the water level in
the pressure regulator.
- Clean the filter insert.
The water level should not climb to the
filter insert 1.
- After screwing in the drain screw 3,
blow the water out of the waterseparator
2 under pressure.
Note:
The water separator 2 is equipped with a
semi-automatic condensation drain.
When falling below a certain pressure,
the condensation is automatically
drained.
Dirt and condensation are removed
through filter insert 1.
- Separate the machine from the
compressed air supply.
- Screw in the drain screw 3.
The pneumatic system of the
machine must be pressure-free.
- Screw water separator 2 off.
- Screw filter insert 1 off
Wash out the filter case and filter
insert with naptha (
no
solvents!
) and blow out clean.
- Reassemble the maintenance unit again
and connect.
40
500
25