Operation Manual

"Operator-level" parameter list:
parameter function setting
max. min. pre-set value
Arv
1
starting bar-tack stitches forwards 254 0 2
Arr
1
starting bar-tack stitches backwards 254 0 4
Err
1
ending bar-tack stitches backwards 254 0 2
Erv
1
ending bar-tack stitches forwards 254 0 2
LS
2
light-barrier differential stitches 254 0 6
LSF
2
stitch rate of light-barrier filter 254 0 0
for yard goods
LSn
2
number of light-barrier seams 15 1 1
Stc
stitch rate of seam with stitch- 254 0 10
counting
F
assigns a technician-level 5 1 2
parameter to key 3
1 = needle cooling ON / OFF
2
2 = stroke adjustment ON / OFF
2
3 = stroke adjustment
2
4 = softstart
SAv
1
starting ornamental-stitch bar tack - 254 0 3
stitch count forwards
SAr
1
starting ornamental-stitch bar tack - 254 0 3
stitch count backwards
SEr
1
ending ornamental-stitch bar tack - 254 0 3
stitch count backwards
SEv
1
ending ornamental-stitch bar tack - 254 0 3
stitch count forwards
cFw
2
stitch count residual-thread monitor 2540 0 0
stitch counting
FES
2
operating mode of thread-drawing 6 0 0
mechanism
1
Only by sewing machines with thread trimmer (Subclass 467-183 081) and
electropneumatic seam bartacking and sewing foot lift (RAP 13-4)!
2
Parameter has no function with this machine class!