Operation Manual
Set-up
Operating manual 275 Version 01.0 - 01/201684
6.16.2 Setting the operating pressure
Correct setting
The operating pressure for the pneumatic unit is 6 bar.
Figure 51: Setting the operating pressure
1. Pull the turning handle (1) up.
2. Set the operating pressure in such a way that the pressure
indicator (2) indicates 6 bar:
• To increase the pressure: Turn the rotary handle (1)
clockwise.
• To reduce the pressure:Turn the rotary handle (1)
counterclockwise.
3. Push the turning handle (1) down.
6.17 Oil lubrication
Section 5.21.2 Oil lubrication, page 60
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
Make sure that the operating pressure is set correctly before
putting the machine into operation.
ATTENTIO
0
2
8
4
6
10
1
2
(1) - Rotary handle
(2) - Pressure indicator