Operation Manual
Set-up
Operating manual 275 Version 01.0 - 01/201680
Setting the brightness of the LEDs and the display
1. After calling up the special functions ( page 79), press
sequence key 2.
All LEDs are switched on.
The display (3) shows the Brightness selection:
2. Set the brightness using the Plus/Minus keys (4).
The brightness can be changed in 8 levels.
Level 3 is set when the machine is delivered.
3. Save the desired brightness by pressing the F (6) key twice.
The LED above the key goes out.
The system switches out of the special function mode
back into normal operation.
Moving to the reference position after every thread-cutting
operation.
After switching on the machine the stepper motor for setting the
length of the upper transport moves to the reference position once.
To allow the position of the stepper motor to be checked more
frequently, the stepper motor can also be moved to the reference
position after every thread-cutting operation.
1. After calling up the special functions ( page 79), press
sequence key 4.
The display (3) shows the Reference selection:
2. Change the setting using the Plus/Minus keys (4):
• Move the machine to the reference position only at
switch-on: Set the display to 00.
• Move the machine to the reference position after every
thread cutting operation: Set the display to 01.
The machine is set to 00 when delivered
3. Save the desired Setting by pressing the F (6) key twice.
The LED above the key goes out.
The system switches out of the special function mode
back into normal operation.