Operation Manual
Set-up
Operating manual 275 Version 01.0 - 01/2016 77
6.12.3 Establishing equipotential bonding
The grounding wire conducts any static charging to ground.
Figure 47: Establishing equipotential bonding
1. Attach the grounding wire (2) to the motor using the fastening
screw (1).
2. Lay the grounding wire (2) to the rear side of the controller.
3. Attach the cable lug (3) of the grounding wire (2) to the rear
side of the controller.
Danger to life due to electric shock.
Disconnect the power plug before establishing
equipotential bonding.
Make sure the power plug cannot be
unintentionally reinserted.
DANGER
(1) - Fastening screw
(2) - Grounding wire
(3) - Cable lug
①
①
②
③