Operation Manual
Operation
Operating manual 275 Version 01.0 - 01/2016 37
5.10 Setting the second upper transport length
When using mechanically or electropneumatically switched
multiple widths (additional equipment) a second (larger) upper
transport length can be set at the adjusting wheel (1). The currently
set value is can be read at the pointer (2).
Figure 18: Setting the second upper transport length
Setting the second upper transport length
1. Turn the adjusting wheel (1):
• Larger second upper transport length:
Turn the adjusting wheel counterclockwise.
• Smaller second upper transport length:
Turn the adjusting wheel clockwise.
①
②
(1) - Second upper transport
adjusting wheel
(2) - Pointer