Instruction manual

8. Fullness control in classes 275-142342 and 275-742642
8.1 Checking the basic control setting
Once the machine has been set up the basic control setting
should be checked and adjusted if necessary. In order to
change the basic setting the machine must switched on while
pressing the “F” key.
As soon as the green LED above the “F” key lights up
the key can be released: the LED flashes. On completion of the
internal system check the “special functions” selection is
displayed.
The various special functions are called by pressing keys 1 to 7;
the green LEDs above the keys indicate the function called.
The following sections describe special key functions 2, 4
and 5. The other special functions are described in the
Servicing instructions. Press the “F” key to leave special
functions and switch to normal operation: the LED above the
key goes out.
8.1.1 Setting the LED and display brightness
After calling special functions (see section 8.1), press the key 2.
All the LEDs are switched on. The brightness can be adjusted to
any of 8 levels by pressing the “+/-” keys. Press the “F” key twice
to save the brightness setting and switch to normal operation.
Brightness is factory-set to level “03”.
8.1.2 Moving to the reference position after each thread cut
When the machine is switched on the step motor that sets
the overfeed length moves to the reference position. In order to
check the position of the step motor more often, the step motor
can also be moved to the reference position after each thread
cut. The procedure is as follows:
After calling the special functions (see section 8.1)
press the 4 key.
The function can now be switched with the +/- keys:
display 00 = move to the reference position only when the
machine is switched on.
display 01 = move to the reference position after each thread
cut.
Press the “F” key twice to save the setting and terminate the
function.
The machine is factory-set to “00”.
49