Instruction manual
7.3.8 Setting positions with the V820 operating panel
Setting the reference position
Prerequisite:
The technician-level code has been set. See section 7.3.7.
–
After entering the code press the “E” key: the first technician-level parameter,
F-100, is displayed.
–
Set parameter F-170 withkeys0to9.
–
Press the “E”key.”F-170 Sr1 (o)” appears in the display.
–
Press the “B” key (see illustration 7.3.1).”PoS0 o” appears in the display
(the o character rotates)
–
Turn the handwheel in the normal direction of rotation until the rotating character
“o” in the display goes out, then turn it further until the reference position is
reached (turn the handwheel to point “F”).
–
Press the “P” key: the reference position is saved and the current parameter
number is displayed.
–
If the error message “A3” is displayed, the setting must be repeated.
–
Press the “P” key: programming at technician level is terminated.
Setting positions 1 and 2
Prerequisite:
The reference position has been set and the technician-level code entered (see above).
–
Enter parameter “F-171”.
–
Press the “E”key:“Sr2 (o)” appears in the display.
–
Press the “B” key (see illustration 7.3.1). “P1E xxx” appears in the display.
(xxx = parameter value of position 1E)
–
Correct the parameter value * if necessary, either with the “+” and “-”keys,with
keys 0 - 9 or by turning the handwheel to point “F”.
–
Press the “E”key:“P2E xxx” appears in the display.
(xxx = parameter value of position 2E)
–
Correct the parameter value * if necessary, either with the “+” and “-”keys,with
keys 0 - 9 or by turning the handwheel to point “C”
–
Press the “E”key:“P1A xxx” appears in the display.
(xxx = parameter value of position 1A)
–
Correct the parameter value * if necessary, either with the “+” and “-”keys,with
keys 0 - 9 or by turning the handwheel.
–
Press the “E”key:“P2A xxx” appears in the display.
(xxx = parameter value of position 2A)
–
Correct the parameter value * if necessary, either with the “+” and “-”keys,with
keys 0 - 9 or by turning the handwheel.
–
Press the “P” key twice to leave the programming level when the settings are
complete.
–
Check the positions: see section 6.8.
46