Instruction manual

7.3.8 Setting positions with the V820 operating panel
Setting the reference position
Prerequisite:
The technician-level code has been set. See section 7.3.7.
After entering the code press the E” key: the first technician-level parameter,
F-100, is displayed.
Set parameter F-170 withkeys0to9.
Press the E”key.”F-170 Sr1 (o) appears in the display.
Press the B” key (see illustration 7.3.1).”PoS0 o” appears in the display
(the o character rotates)
Turn the handwheel in the normal direction of rotation until the rotating character
o in the display goes out, then turn it further until the reference position is
reached (turn the handwheel to point “F”).
Press the P key: the reference position is saved and the current parameter
number is displayed.
If the error message “A3 is displayed, the setting must be repeated.
Press the P key: programming at technician level is terminated.
Setting positions 1 and 2
Prerequisite:
The reference position has been set and the technician-level code entered (see above).
Enter parameter “F-171”.
Press the E”key:“Sr2 (o)” appears in the display.
Press the B” key (see illustration 7.3.1). “P1E xxx” appears in the display.
(xxx = parameter value of position 1E)
Correct the parameter value * if necessary, either with the +” and -”keys,with
keys 0 - 9 or by turning the handwheel to point “F”.
Press the E”key:“P2E xxx” appears in the display.
(xxx = parameter value of position 2E)
Correct the parameter value * if necessary, either with the +” and -”keys,with
keys 0 - 9 or by turning the handwheel to point “C
Press the E”key:“P1A xxx” appears in the display.
(xxx = parameter value of position 1A)
Correct the parameter value * if necessary, either with the +” and -”keys,with
keys 0 - 9 or by turning the handwheel.
Press the E”key:“P2A xxx” appears in the display.
(xxx = parameter value of position 2A)
Correct the parameter value * if necessary, either with the +” and -”keys,with
keys 0 - 9 or by turning the handwheel.
Press the P key twice to leave the programming level when the settings are
complete.
Check the positions: see section 6.8.
46