7.3.4 Changing parameter values at operator level
The operator-level parameters are given in the parameter list in section 7.1.3.
Turn on the main switch.
Press the P key: the first operator-level parameter, “F-000 c2”, is displayed.
The parameters can be selected by pressing the “+”or“-”key.
Press the E key: the value of the selected parameter, e.g. F-000 c2 002”, is
displayed.
The value 002 can be changed by pressing the +”or“-”key.
Press the E key to save the changed value provisionally and display the next
parameter, or the “P” key to save the changed value provisionally and display the
same parameter.
Press the P key to save the change permanently and leave the programming
level.
7.3.5 Reducing the maximum speed
The maximum speed can be reduced to adapt it to particular applications.
After each completed seam the current value of the maximum speed is shown in the
display. This value can be directly changed with the +”or“-”keys.
The adjustment range lies between the values of parameters F-111 (maximum value)
and F-121 (minimum value).
NB:
There are two settings for the maximum speed: the value of parameter 111 and the
reduction in maximum speed with the “+/-” keys. The lower value always has priority. If
the maximum speed is reduced with the “+/-” keys, an increase in the value of
parameter 111 takes effect only if the reduction is cancelled.
CAUTION:
The maximum speed (the value of parameter 111) should
not be set higher than the figure shown in the parameter
sheet (in the accessory kit) for machines of the relevant
class and subclass.
7.3.6 Quick information and quick settings entry (HIT)
When functions are switched on with keys 1, 2, 3, 4 and 9 the associated values are
displayed to the operator for about 3 seconds. During this period the value can be
changed immediately with the +”or“-”keys.
44