Instruction manual
CAUTION:
The changed parameter values are not saved unless a
complete seam is sewn after leaving the programming
level, i.e. the pedal is pushed forwards and then all
the way back.
If the drive is switched off straight after leaving the
programming level, the changes are lost.
7.2.7 Setting positions with the V810 operating panel
Setting the reference position
Prerequisite:
The technician-level code has been entered. See section 7.2.6.
–
Press the “E” key: the first technician-level parameter, “F-100”, is displayed.
–
Use the “+”, “-” and “>>” keys to set the “F-170” parameter.
–
Press the “E”key:“Sr1 (o)” appears in the display.
–
Press the “>>“key: “PoS0 o” appears in the display (the o character rotates).
–
Turn the handwheel in the normal direction of rotation until the rotating character
“o” in the display goes out, then turn it further until the reference position is
reached (turn the handwheel to point “F”).
–
Press the “P” key: the reference position is saved and the current parameter
number is displayed.
–
If the error message “A3” is displayed, the setting must be repeated.
–
Press the “P” key to terminate programming at technician level.
Settings positions 1 and 2
Prerequisite:
The reference position has been set and the technician-level code has been entered
(see above).
–
Enter the parameter “F-171”.
–
Press the “E”key:“Sr2 (o)” appears in the display.
–
Press the “>>”key: “P1E xxx” appears in the display (xxx = parameter value of
position 1E).
–
Correct the parameter value * if necessary, either with the “+”or“-”keysorby
turning the handwheel to point “F”.
–
Press the “E”key:“P2E xxx” appears in the display (xxx = parameter value of
position 2E).
–
Correct the parameter value * if necessary, either with the “+”or“-”keysorby
turning the handwheel to point “C”.
–
Press the “E”key:“P1A xxx” appears in the display (xxx = parameter value of
position 1A).
–
Correct the parameter value * if necessary, either with the “+”or“-”keysorby
turning the handwheel.
–
Press the “E”key:“P2A xxx” appears in the display (xxx = parameter value of
position 2A).
39
GB