Instruction manual

7.1.8 Condition and error messages
General information
DA220C V810 V820 Meaning
A1 InF A1 InFo A1 The pedal is not in its zero position
when the sewing drive is switched on
A2 “StoP” flashes “StoP” flashes The cut-out is active
+ Symbol
“cut-out”
A3 InF A3 InFo A3 The reference position is not set.
For programming see sections 7.1.5, 7.2.7
and 7.3.8.
A5 InF A5 InFo A5 No valid Autoselect resistance has been
detected.
Emergency-operation function:
for information see section 6.8.2.
Programming error messages (parameters)
If an incorrect code or parameter is entered, the following error message appears
(depending on the operating panel used):
DA220C returns to “000” or the last parameter number
V810 returns to “0000” or the last parameter number
V820 as with V810, plus display “InF F1”
Hardware and software error messages
DA220C V810 V820 Meaning
E2 InF E2 InF E2 Mains voltage too low or time between
main switch OFF and main switch ON too brief.
E3 InF E3 InF E3 Machine blocked or not reaching the
required rpm
E4 InF E4 InF E4 Control problem due to defective earthing
or faulty plug connections (contact faults).
h1 InF h1 InF h1 The commutating-transducer lead is defective or
the power electronics that generate the
rotating field are faulty.
h2 InF h2 InF h2 Processor faulty.
34