Instruction manual
Entering the manufacturer-level code with the DA220C control
–
Turn off the main switch.
–
Press and hold down the “P”key.
–
Turn on the main switch: “Cod” appears in the display.
–
Release the “P”key.
–
Enter code 311. Press the “+” or “-” keys to change the value of the flashing figure.
Press the “>>” key to move to the next figure.
–
Press the “E” key: the first manufacturer-level parameter, “2.0.0.”, is displayed.
–
Continue as described under “Selecting parameters and changing values”.
CAUTION:
The changed parameter values are not saved unless a
complete seam is sewn after leaving the programming
level, i.e. the pedal is pushed forwards and then all the way
back.
If the drive is switched off straight after leaving the
programming level, the changes are lost.
7.1.5 Setting positions with the DA220C control
Setting the reference position
Prerequisite:
The technician-level code has been set (see section 7.1.4).
–
Press the “E” key: the first technician-level parameter, 1.0.0., is displayed.
–
Use the “+”, “-” and “>>“ keys to enter parameter 1.7.0..
–
Press the “E”key:“Sr1” appears in the display.
–
Press the “>>“key:“Po” appears in the display (the “o” character rotates).
–
Turn the handwheel in the normal direction of rotation until the rotating character
“o” in the display goes out, then turn it further until the handwheel reaches its
reference position (position “F”).
–
Press the “P” key: the reference position is saved. The current parameter number
is displayed.
–
Press the “P” key to terminate technician-level programming.