Instruction manual

7.1.4 Changing technician-level and manufacturer-level parameter values
CAUTION:
Great care must be taken when changing parameter values,
as an incorrectly-set drive control may damage the
machine.
NB:
A master reset restores all parameters to the values pre-set by the drive manufacturer.
See section 7.1.7.
Entering the technician-level code with the DA220C control
Turn off the main switch.
Press and hold down the “P”key.
Turn on the main switch: cod” appears in the display.
Release the P”key.
Press the >>“key:“000” appears in the display. The left-hand figure flashes.
Enter code 190. Press the “+” or “-” keys to change the value of the flashing figure.
Press the >>“ key to move to the next figure.
Press the E key: the first technician-level parameter, 1.0.0.”, is displayed.
Selecting parameters and changing values
Use the +”, “-” and >>” keys to set the required parameter
(see section 7.1.1.2).
Press the E key: the value of the parameter is displayed.
Press the +”or“-” keys to change the value of the parameter.
Press the E key to display the next parameter or the “P”key
to display the same parameter.
Saving changed parameter values
Press the P key to end programming.
Sew a complete seam, i.e. push the pedal forwards, then all the way back: the
change is saved.
If no seam is commenced, the change is lost.
Press the P key again to return to programming level.
29
GB