Instruction manual
7.1.3 DA220C control operator-level parameter list
Parameter adjustment range
pre-set value
No. Abb. Name/Function min max 100R
000 c2 starting-bar-tack stitches forwards 0 254 2
001 c1 starting-bar-tack stitches backwards 0 254 4
002 c3 ending-bar-tack stitches backwards 0 254 3
003 c4 ending-bar-tack stitches forwards 0 254 3
004 LS number of light-barrier equalising stitches 0 254 4
(large stitch length)
005LSF number of light-barrier filter stitches for 0 254 0
knits
006LSn number of seams terminated with 0 15 1
the light barrier
007Stc number of stitches in the 0 254 10
automatically-produced seam section
008 -F- assigning a function to key 9 (on the 1 5 2
V820 operating panel)
1 = Softstart ON/OFF
2 = ornamental-stitch bar tack ON/OFF
3 = stroke adjustment
press and release = ON /
press and hold = OFF
4 = needle cooling ON/OFF 1 5 2
009 LS light barrier ON/OFF 0 1 0
010cLS number of light-barrier equalising stitches 0 254 8
(small stitch length)
013 FA thread cutter ON/OFF 0 1 1
014FW thread retractor ON/OFF 0 1 0
015StS stitch count ON/OFF 0 1 0
080Sav number of stitches, starting 0 254 3
decorative-stitch bar tack forwards
081 SAr number of stitches, starting 0 254 3
decorative-stitch bar tack backwards
082SEr number of stitches, ending 0 254 3
decorative-stitch bar tack forwards
083SEv number of stitches, ending 0 254 3
decorative-stitch bar tack backwards
28