Instruction manual
LED Function
LED1 on display for single starting bar tack
LED2 on display for double starting bar tack
LED1 and LED2 off starting bar tack off
LED3 on display for single ending bar tack
LED4 on display for double ending bar tack
LED3 and LED4 off ending bar tack off
LED5 on display for automatic sewing-foot lift on halt in seam
LED6 on display for automatic sewing-foot lift after thread cut.
LED7 on display for basic needle position = down
LED8 on display for basic needle position = up
display3-figure display for rpm, parameters and code
7.1.1 Changing parameter values at operator level with the DA220C control
Operator-level parameter values (see parameter list in section 7.1.3) can be changed
without entering a code.
7.1.1.1 Calling and changing operator-level parameters one after the other with
the DA220C control
–
Turn on the main switch.
–
The value for the maximum speed appears in the display, e.g. “480” for 4800 rpm.
–
Press “P”: the first parameter, “0.0.0.”, is displayed.
–
Press “E”: its associated parameter value, e.g. “002”, is displayed.
–
Press “+”: the parameter value is increased.
–
Press “-”: the parameter value is reduced.
–
Press “E”: the next parameter, “0.0.1.”, is displayed.
–
Press “E”: the value of parameter “0.0.1.”, e.g. “004”, is displayed, and so on.
In this way all the operator-level parameters can be displayed and changed one
after the other. After the last parameter programming at operator level terminates.
You can leave programming at operator level at any time:
–
Press “P”: the same parameter, “0.0.1.”, is displayed.
–
Press “P” again to leave programming at operator level. The value for the maximum
speed appears in the display, e.g. “480” for 4800 rpm.
–
On termination of programming at operator level the changed values are saved.
26