Instruction manual

7.1 DA220C control operating and display elements
Key Function in sewing mode (main switch on)
P enter / leave programming mode
E starting bar tack single / double / off
(displayed by LED1 and LED2)
+ ending bar tack single / double / off
(displayed by LED3 and LED4)
- automatic sewing-foot lift on halt in seam on/off
(displayed by LED5)
automatic sewing-foot lift after thread cut on/off
(displayed by LED6)
>> basic needle position: position 1 (displayed by LED7)
or position 2 (displayed by LED8)
Key Function in programming mode
(see section 7.1.1)
P enter / leave programming mode
E call parameter value or confirm change
+ increase number or parameter value
- reduce number or parameter value
>> Shift function
25
GB
LED 1
LED 8