Instruction manual

6.7 Checking the positioning
Needle positions are correctly set prior to delivery, but they should still be checked
before starting the machine.
NB:
The sewing foot must be locked in the up position (see Operating instructions,
section 6.13).
The machine must move to an intermediate halt in position 1 (needle down).
See section 7.1, LED 7.
Position 1
Turn on the main switch.
Briefly push the pedal forwards and return it to its original position. The needle
moves to position 1 = handwheel point “F”.
Check the position of the needle.
Position 2
Move the pedal forwards, then fully back.
The needle moves to position 2 = handwheel point “C”.
Check the position of the needle.
If either or both needle positions are incorrect, they must be corrected:
see section 7.1.5 or 7.2.7.
6.8 Machine-specific parameters
6.8.1 General
The functions of the sewing-drive control are determined by the program and the
parameter settings.
All parameter values for the relevant machine class and subclass are correctly set prior
to delivery. This entails changing some pre-set control values (e.g. the maximum
speed). If the control is replaced, the machine-specific parameters must be restored to
their correct values. See section 7.1.6, 7.2.8 or 7.3.9.
6.8.2 Autoselect
The control “recognises” which machine series is connected by measuring the
Autoselect resistance in the machine. Autoselect selects control functions and the
pre-set parameter values.
Caution: If the control fails to recognise a valid Autoselect resistance (or any at all), the
drive runs only with the so-called emergency operating functions to prevent machine
damage.
6.9 Master reset
A master reset (see section 7.1.7, 7.2.9 or 7.3.10) resets all parameters to their pre-set
values. After a master reset the machine-specific parameters must be restored to their
correct values. See section 7.1.6, 7.2.8 or 7.3.9.
23
GB