Instruction manual

6.18 Fullness control (Cl. 275-142342, 275-742642)
6.18.1. General
This fullness control permits the “semi-automatic” processing of various fullnesses
within a s eam. 30 programs with up to 8 s equences each can be stored. In each
sequence the set length of the overfeed is shown in the display, and it can be changed
manually at any time. Operating the knee switch moves from one sequence to the next;
this happens automatically at the end of a seam when the thread is cut.
6.18.2. Operating terminal - description of the operating components
“Smooth-sew ing” key
When this key is operated the green LED above the key
lights up and the material is “smooth-sewn”, i.e. with no
gathering. The length of the overfeed must be set (with the
+/- keys) so that the material is sewn with no gathering.
Keys 1 to 8 “sequence”
With the keys 1 to 8 the required sequence within a
program can be directly switched on. The LEDs above the
keys display the following states:
green LED on = current sequence
red LED on = inactive sequence
both LEDs off = active sequence
both LEDs on = this current sequence was switched on
manually. It is skipped in the sequence advance.
25
GB