8.2.11 Malfunction and Error Messages in the DA40MS Controls and
the OC-TOP Control Panel
At intervals the controls check their own operativeness and that of the drive.
Malfunctions are indicated by the LED H1 in the controls or in the display of the control
panel, e.g.
No. Type of malfunction OC-TOP DA40MS
DA40MS02
1 The pedal is not in the zero position at mains ON ERROR 01 -
9Start lock ERROR 09-
10 The machine class was changed.
Remedy: Turn the mains switch off and on again ERROR 10 -
62 Short curcuit at 24V (32V) direct-current ERROR 62 LED H1 blinks
63 Overload of the 24V (32V) direct-current, ERROR 63 LED H1 blinks
Load current > 4A.
64 Mains voltage too low (90 - 150V) ERROR 64 LED H1 blinks
65 The power electronics are not operational after ERROR 65 LED H1 blinks
mains ON. (Mains voltage < 130V)
66 Ground contact. Motor or motor lead have a ground ERROR 66 LED H1 blinks
contact in one or more phases.
67 Internal malfunction ERROR 67 LED H1 blinks
68 a) Excess current, short curcuit in the motor or ERROR 68 LED H1 blinks
in the motor lead
b) Overvoltage, mains voltage too high (>300V).
c) Undervoltage
70 Machine blocked, no increment impulses ERROR 70 LED H1 blinks
come from the synchronizer at maximum
motor torque.
71 The lead of the commutation initiator is not ERROR 71 LED H1 blinks
plugged in.
73 The motor is overloaded. ERROR 73 LED H1 blinks
75 Internal malfunction ERROR 75 LED H1 blinks
90 EEPROM is not present ERROR 90 LED H1 blinks
91 EEPROM is not programmable ERROR 91 LED H1 blinks
92 Start lock at motor run ERROR 92 LED H1 blinks
93 EEPROM is false ERROR 93 LED H1 blinks
100 - Internal malfunction ERROR ... LED H1 blinks
117
8.2.12. Seam Programming with the OC-TOP Control Panel
5 sewing programs with 5 seam runs each can be programmed with the OC-TOP control
panel. Description see Operating Instructions MINI-STOP QE3760 Typ DA40MS.