Operation Manual
Table Of Contents
- 271743-01-Deckblatt
- 271743-02-VoSi -D-
- 271743-03-Inhalt-D-1
- 271743-04-Inhalt-D-2
- 271743-05-VoSi -GB-
- 271743-06-Inhalt-GB-1
- 271743-07-Inhalt-GB-2
- 271743-08-VoSi -F-
- 271743-09-Inhalt-F-1
- 271743-10-Inhalt-F-2
- 271743-11-VoSi -E-
- 271743-12-Inhalt-E-1
- 271743-13-Inhalt-E-2
- 271743-14-VoSi -P-
- 271743-15-Inhalt-P-1
- 271743-16-Inhalt-P-2
- 271743-17-VoSi -I-
- 271743-18-Inhalt-I-1
- 271743-19-Inhalt-I-2
- 271743-Standbogen

8.2.6 Changing Parameters at the "Mechanic Level" and the "Special Level" with
the OC-TOP Control Panel
A change in the parameter values is e.g. necessary for the setting of the needle positions
(Chapter 8.2.7) and the setting of the machine-specific parameters (Chapter 8.2.9).
Preparation for activation of the "Mechanic Level (B)".
–
Turn the mains switch off.
–
Hold the 5 (P/M) and 6 (T/E) keys pressed and turn the mains switch on.
–
Release the 5 (P/M) and 6 (T/E) keys, the display shows an "*" (number 11)
between the program number (numbers 9 and 10) and the seam run
(numbers 12 and 13).
–
Sewing is possible.
Example
Activating the "Mechanic Level (B)"
Prerequisite:
Key 5 (P/M) is not lit.
–
Press the 6 (T/E) key (lit)
–
With the numbers 10 to 12 a parameter number (the first time 104, thereafter the
last selected) and with the numbers 14 to 16 the corresponding parameter value is
shown.
–
Sewing is not possible.
Example
Changing the parameter number and the parameter value
–
The hundreds of the parameter number are changed with the P+ or P- keys.
–
The tens and ones of the parameter number are changed with the S+ or S- keys.
–
The parameter value is changed with the L+ or L- keys.
GB
65