8.2.4 Changing Parameters at the Operator Level (A)
The parameter values at the operator level (see Parameter List 8.2.5) can be changed
as follows.
Turn the mains switch on, do not operate the pedal.
The "Manual Sewing" work mode is active (the LED in the key 5 (P/M)) is dark).
Press the 6 (T/E) key, the LED is lit, sewing is no longer possible.
The first parameter at the operator level is shown in the display.
Example:
NumberMeaning Change via:
1 Number of forward stitches in the beginning bartack
3 Number of reverse stitches in the beginning bartack
5 Number of reverse stitches in the end bartack
7 Number of forward stitches in the end bartack
10 Parameter number (hundreds) P+ or P- key
11 Parameter number (tens) S+ or S- key
12 Parameter number (ones) S+ or S- key
14-16 Parameter value L+ or L- key
The parameter value can be changed with the L+ or L- key
The parameter number can be changed with the P+ or P- key (hundreds) or with
the S+ or S- key (tens and ones).
Press the 6 (T/E) key, the setting is saved, the operator level A is exited, the LED is
dark and sewing is possible again.
8.2.5 Parameter List at the Operator Level (A)
Parameter Setting RangePreset
No. Abbr. Designation/Function min max 100R
111 LS Light barrier compensation stitches 1 255 6
112 LS Number of stitches to the light barrier mark 0 255 0
by knitted goods
116 SANL Number of softstart stitches 0 255 2
148 AR Beginning bartack-double = I, single = II I II I
149 ER End bartack-double = I, single = II I II I
450 LS/STL Light barrier compensation stitches by short 1 255 6
sewing length
523 RIE/ Change-over fancy-stitch bartack = I, I II II
ZRIE normal bartack = II