8.1.13 Master Reset at the DA40MS02 Controls
All parameter values changed in relation to the preset values are reset to the preset
values by a master reset.
ATTENTION!
At a master reset several parameters such as e.g.
<700-707> (needle positions), <799> (selected machine
class) and
<800> (motor direction of rotation) are not reset.
After a master reset all machine-specific parameters
must be set as per the parameter sheet again. See
Chapter 8.1.12
Preparing the Master Reset
–
Turn the main switch off.
–
Step the pedal completely forward and hold in this position.
–
Press the keys M- and V- at the same time and hold down.
–
Turn the main switch on.
Display
Display master reset
Conducting a Master Reset
–
Press the M+ key.
–
The master reset is initiated. If the master reset is not to be carried out, then the
M- key must be pressed.
–
The display shows the display mode 1.(See Chapter 8.1.2).
60