Operation Manual

8.1.4 Reducing the Maximum Speed in the DA40MS02 controls
In order to optimally set the maximum speed of the machine to the current individual
application, a reduction of the maximum speed is possible.
Prerequisites:
The mains switch is turned on.
The pedal is in base position.
Sewing is not taking place.
The display mode 2 is turned on (see Chapter 8.1.2).
Display:
Display mode 2: Maximum speed
Number Meaning Change via:
1 Character for the speed display -
3-6 Stitches-rpm V+ or V- key
8 Current programming level Chapter 8.1.7, 8.1.8, 8.1.9-
Reducing the maximum speed
Press the V- key, the maximum speed is lowered
Press the V+ key, the maximum speed is increased
Note!
The setting range lies between the parameter value <607> (maximum) and <606>
(minimum).
ATTENTION!
The maximum speed (value of the parameter 607) should
be set no higher than is listed in the parameter sheet (in
the accessories pack) for each class and subclass..
52