Operation Manual

6.4 Connection Sockets on the DA220C and DA40MS02 Controls
6.5 Connecting the DA220C Controls
Insert the lead from the controller (pedal) into socket B80 of the controls.
Insert the lead from the motor sensor 2 into socket B2 of the controls.
Insert the lead 1 from the motor into socket B41 of the controls.
Insert the lead to the sewing machine into socket A of the controls.
Lay all leads through the cable duct.
Insert the lead from the control panel (if present) into socket B776.
6.6 Connecting the DA40MS02 Controls
Insert the lead from the controller (pedal) into socket X3 of the controls.
Insert the lead from the motor sensor 2 into socket X2 of the controls.
Insert the lead 1 from the motor into socket X1 of the controls.
Lay all leads through the cable duct.
Insert the lead from the control panel (if present) into socket X4.
1
2
B776
V 8 . .
B18
L S M ...
B2
M
B80
EB...
B41
M
A
X1
Motor
X2
X4
X3
A
20