Operation Manual

Maintenance Unit
Element Function
7 - Oil mister - With the regulating screw 5 set approx. 1 drop
for 10 work cycles. To fill interrupt the
compressed air feed and vent the system with
screw 9. Screw out screw 6 and fill
"Esso SP NK 10"-type oil up to the groove in
the glass.
8 - Air filter and - Before the water level reaches the filter, screw
water trap in screw 9 far enough to drain water.
Do
not
interrupt the compressed air supply.
10 - Pressure Regulator - To set to 6 bar pull the bushing 11 up
and turn appropriately.
UMBRUCH =
11 10 9 8 7 6 5
12