Maintenance work Explanation Operating
to be carried out hour
Sewing drive
Clean the motor ventilation
grille (e.g. with an air blow
gun)
Clean the air inlets from sewing dust and
thread remainders
8
Pneumatic system
Check the water level in the
pressure regulator.
Clean the filter insert.
Make leak test of the system.
The water level must not rise up to the filter
insert 1.
- Drain water out of the water separator 2
under pressure after screwing out
the drain screw 3.
Dirt and condensed water are discharged
through the filter insert 1.
- Separate the machine from the
compressed air supply.
- Screw out drain screw 3.
The pneumatic system of the machine
must be pressureless.
- Screw off the water separator 2.
- Screw off the filter insert 1.
Wash out dirty filter pan and
filter insert with benzine (no
solvent) and blow them clean.
- Reassemble the maintenance unit.
40