Operation Manual

Altering the machine parameters
Parameter 30: Set the main speed
Setting range: 0 - 6500
Parameter 31: Manual sewing on/ off
Setting range: 0 / 1
Parameter 32: Number of stitches how long the table blowing
remains switched on
Setting range: 0 …400 stitches
Parameter 33: Number of stitches until the automatic start engages
after the sewing start
Setting range: 0 ...
Parameter 34: Number of stitches until the contour guide lowers
Setting range: 0 …400 stitches
Parameter 35: Number of stitches until the contour guide retracts
laterally
Setting range: 0 …400 stitches
Parameter 36: Number of stitches until the feeding unit lowers
Setting range: 0 ...400
Parameter 37: Start mode contour modulation
1 = front, left
2 = rear, right
3 = rear, left
Setting range: Modes 1, 2, 3
Parameter 60: Soft start speed
Setting range: 500 ...5000
Parameter 61: Switch the soft start on or off
Setting range: 0 / 1
Parameter 76: Switch the start on or off via light barrier
Setting range: 0 / 1
Parameter 77: Switch the autostart on or off
Setting range: 0 / 1
Parameter 78: Number of stitches until the autostart starts
Setting range: 0 ...400 stitches
30