Setting the ejector roller
Via this parameter the ejector roller is set.
Parameter 16: Number of stitches how long the seam chain
is sucked (seam beginning)
Setting range: 0....120
Parameter 17: Switch the stacker on or off
Setting range: 0 / 1
Parameter 20: Number of stitches when the ejector roller lowers
Setting range: 0 …400 stitches
Parameter 21: Number of stitches how long the ejector roller is
switched on
Setting range: 0 …400 stitches
Parameter 22: Number of stitches after “light barrier bright”, until
the ejector roller stops
Setting range: 0 …30 stitches
Parameter 23: Time how long the ejector roller is active
Setting range: 0 …1000
Parameter 47: Time of the stacker movement
Input: 0 …2000
Parameter 53: Time when the ejector roller lifts
Setting range: 0 …2000
Setting the puller
Via this parameter the puller is set.
Parameter 26: Number of stitches when the puller lowers
Setting range: 0 …400 stitches
Parameter 27: Number of stitches how long the puller remains
lowered
Setting range: 0 …400 stitches
Parameter 51: Puller speed
lower value = increased puller speed
higher value = lower puller speed
Setting range: 400 … 1000
Parameter 100: Number of stitches how long the puller lifts
Setting range: 0...400 stitches
29