Operation Manual

6.4.1 Altering seam-specific parameters
Needle feed (with cylinder)
Via this parameter the needle feed is set.
Parameter 01: Line 1
Number of stitches until the needle feed engages
Setting range: 0 - 2000
Parameter 02: Fullness line 1 ON/ OFF
Setting range: 0 / 1
Parameter 03: Line 2
Number of stitches how long the needle feed is
engaged
Setting range: 0 - 2000
Parameter 04: Fullness line 2 ON/ OFF
Setting range: 0/1
Parameter 05: Line 3
Number of stitches how long the needle feed is
engaged
Setting range: 0 - 2000
Parameter 06: Fullness line 3 ON/ OFF
Setting range: 0/1
Needle feed (with step motor)
Via this parameter the needle feed with step motor drive is set.
Parameter 01: Line 1
Number of stitches
Setting range: 0 - 2000
Parameter 02: Fullness in line 1
Setting range: 0 - 2000
Parameter 03: Line 2
Number of stitches
Setting range: 0 - 2000
Parameter 04: Fullness in line 2
Setting range: 0 - 2000
Parameter 05: Line 3
Number of stitches
Setting range: 0 - 2000
Parameter 06: Fullness in line 3
Setting range: 0 - 2000
27