Operation Manual
6.4.3 Input - Output test
Via the input - output test the different input and output elements can
be checked.
Input test
–
Press key “P”.
–
Press key “8”.
–
Actuate the corresponding input.
Example:
Cover the light barrier.
–
Press key “Program stop”.
The program is quitted.
Input elements
Switch Designation
01 Light barrier 01
04 Knee switch
05 Switch “Program stop”
11 Potentiometer differential bottom and needle feed
(optional equipment)
Output test
–
Press key “P”.
–
Press key “8”.
–
Press key “Plus”.
–
Select the output element to be tested with the keys “Plus” or
“Minus”.
–
Switch the output on or off with the key “F2”.
–
Press key “Program stop”.
The program is quitted.
Output elements
Switch Designation
Y01 Sewing foot up
Y02 Thread tension lift open
Y03 Contour guide up / down
Y04 Stacker on
Y05 Holding stamp up / down
Y07 Contour guide forward / backward
Y08 Contour guide blowing on
Y09 Move contour guide laterally
Y10 Differential bottom feed on / off
Y11 Needle feed on / off
Y12 Warp separator off / on
Y13 Table blowing off / on
Y14 Dirt suction off / on
1