Operation Manual

2.6.6Spring tension ofthe U-shaped spring
Caution:Risk ofinjury!
Switch the m ainswitch off.
C heck and adjustthe top feed onlywiththe sew ing unitsw itched off.
Standard and checking
The spring tensioncanbesetindividuallyoronafixed value.
C orrection w ith a fixed value
Loosen counternut2.
Turn screw 1 insuchawaythatthere isadistance of4 m m
betw een the low eredge ofthe screw head and the counternut.
Tighten counternut2.
Individualcorrection
R em ove pressure spring 3.
M easure the spring tension w ithaspring balance.
Loosen counternut2.
Turn screw 1 correspondingly.
Tighten counternut2.
M ountpressure spring 3 again.
21
3
2
1
1
3