Operation Manual
Adjustm entin sew ing direction
Standard and checking
The distance betw een hook tip 7 and needle 8 should am ountto
0.0-0.05mm.
–
Turn handw heelindire c tion ofrotation untilthe hook tipis exactly
atthe levelofthe m iddleofthe needle.
–
Adjustthe hook support5 w iththe screw 6 insuchawaythatthe
distance betw een hook supportand needle am ountsto0.0-0.05
mm.
–
C heck the cross-line adjustm entonce again and readjust,if
necessary.
–
Tighten screw 4.
6
4
7
8
0-0,05 m m
6
5