Operation Manual

3.5.2 M oun ting the al ter na ting sta cker
Approach the stacker 1 with the holder 2 to the sew ing unit.
Screw the holder 2 on the sew ing unit with two screw s 5.
Align the stacker in such a way that the shield 3 is in parallel
position to the edge of the table top 4.
Tighten screw s 5.
Pneum atic connections fo r th e shield 3
Push the com pressed air line 7 on the com pressed air distributor 8
of shield 3.
Push com pressed air lines (32) on cylinder (32)
Push black cable 9 on valve 8.
Push blue cable 10 on valve 11.
8
4 3 2 1 2 5
3 8 7
11 10 (32) 9 8