Operation Manual

6.11.5F3=Diagnostics
The m enu D IAG NO STICS includes service functions fortesting sew ing
units,aggregates as w ellas the initiators foractivating the aggregates.
F1 = Service test
F1 = M em ory test
F1 = EEPRO M 2K
F2 = EEPRO M 8K
F3 = RAM 8K
F4 = I/O M odulelong-term test
F5 = I/O A nalog output
F6 = Furthertests
F1 = R S 232 Test
F2 = I/O A daptertest
F3 = C om m unication test
F4 = Sewing head test
F1 = Activating the sew ing m otor
F2 = Sewing m otorand puller
F3 = Ejector
F4 = Top feed
F5 = Differential
F6 = Reference value transm itter
Press key P.
The program m ing leveliscalled up.
Press key F3”.
The function D IAGNOSTICS iscalled up.
Callup the testfunctions.
Note
These service functions should only b e c a rried outunderthe guidance
ofthe B eislerservice departm entorin cooperation w ith experienced
service personnel.
A tte n tion:Risk ofbreakage!
During the testsindividualm achine aggregates orm achine sequences
are started.Ifcom ponents have been disassem bled com pletelyor
partiallyorifthey are notoperational,m achine com ponents m ay be
dam aged.
Makeatestonly w hen the m achine is ready foroperation.
F1 = Service test/F1 = M em ory test
ATTENTION !
Alldatainthememories are deleted.
F1 = EEPRO M 2K
F2 = EEPRO M 8K
F3 = RAM 8K
1
53