Operation Manual
6.10 Input-O utputtest
Viathe input-output-testititpossibletoselectthe inputs and outputsof
the sew ing unitcontro l fortrouble shooting and forchecking individual
machine steps.
The outputs(Out)are called up and tested separately. T h e
corresponding inputs(Inp)are indicated w iththe active output.
Activated inputs /outputs are m arked by highlighted identification
num bers.
Inputtest
The inputsaretested dire c tly.
Exam ple:P hotocell13
–
Pushapiece ofpaper1 betw een photocell13 and supportsheet.
InputN o.13 isblack-shadow ed.
O utputtest
–
Press key “F1”.
You gettothe userlevel2.
–
Press key “F8”.
–
Selectthe colum n ofnum bers w iththe keys “ñ “or“ò”.
–
Selectthe identification num berw iththe keys “ï“or“ð “.
–
Press key “E N T”.
The identification num berisblack-shadow ed and the outputis
activated.
–
Press key “E N T”once again.
The outputis deactivated.
Inputelem ents
Signal InputNo.
S02 02 GND bridge on photocell15,ifw ithout
hem recognition “FZ 15”
S04 04 Push-button lining clam p
S05 05 Push-button fusing start
S09 09 Thread m onitor
S13 13 Photocellprogram start
S15 15 Photocellhem recognition
S16 16 Photocellcontourcontro l
47
1
1