Operation Manual
06DURATION OF KETTUP AT THE SEAM END
Duration ofthe kettup function atthe seam end.
Switch offto save energy.
07THREAD LIFTING AT THE SEAM END
The num berofstitches untilthe needlethread isreleased atthe seam
end.
08FZ BLOCKING TIME ATTHE END
Tim e delay forfeeding a new w orkpiece (blocking timeafterlight
b a rrierunblocked).
09PHOTOCELL15ON/OFF
Switching status ofphotocellF15 onlyavailablewith optionalfusing
station.
01 = Function on
00 = Function off
Ifno lightbarrieris m ounted,an errorm essage appears.
10 STACKER -> EJECTOR DOW N
The timethe ejectorislow ered and fixes the w orkpiece untilitistaken
overby the stacker.
11CONTOUR SCANNING TIME
R esponse timeforaltering the pullerspeed (photocell16)
12THREAD MONITOR SENSITIVITY
Setting ofthe thread m onitor
00 = Function off
01 = H igh sensitivity
99 = Low sensitivity
(the setting depends on the sew ing thread used)
13EFKA POSITION UP
N eedle position dow n atthe sew ing start,needle position up w hen
threading.
41