Operation Manual

Selection ofm achin e p a ra m e te rs
The sewing behaviourofthe sew ing unitis determ ined by the settings.
01SEW ING AT LOW SPEED
R educed sew ing speed during the sew ing start(softstart).
02SEW ING AT HIGH SPEED
Mainsewing speed.
03SEW ING START AT LOW SPEED
Section ofdecelerated sew ing start(softstart).
05SEAM SECTION UNTILCONTOUR GUIDE DOW N
S eam section sew n fro m the sew ing startuntilthe contourguide is
low ered.
06UNTIL TABLE BLOW ING ON
S eam section sew n fro m the sew ing startuntilthe blow ing nozzles of
the w orktable are provided w ith com pressed air.
07DURATION OFTABLE BLOW ING
The section overw hichaworkpiece is additionallytransported by
com pressed air.
09REDUCED SPEED
R educed speed ofthe sew ing head sw itched on w iththe function
SEW ING AT LOW SPEED fordifficultseam sectio n s (S 1 - S 5 ).
Reference point= lightbarrierF13 orF15).
39