Operation Manual
Low puller speed atthe hip bow
The param eteralters the basicvalue ofthe pullerspeed w hen sew ing
offthe hip bow .
The pullerspeed can be adapted tothe shape ofthe hip bow .
(in conjunction w ith photocell15).
Param eterLow puller speed atthe hip bow
20LOW SPEED AT HIPBOW
Main param eter/Basicsetting ofthe pullerspeed forthe hip bow .
21LOW SPEED UP TO HIPBOW
The seam section sew n w iththe pullerspeed ofthe m ain seam until
the speed is reduced atthe hip bow.(R eference point= photocell15)
22DURATION O F LO W SPEED AT HIPBOW
The seam section sew n atlow speed inthe hip bow.
35 UP TO FLY B LO W ING
The lengthofthe seam section afterunblocked photocell13,untilthe
flyisblow n.
36DURATION OF FLY BLOW ING
Duration ofthe blow ing operation.
11UNTIL BLADE SW IVELS O UT
Transportlengthfro m the photocell13or15untilthe blade sw ivels out.
44 S W IVELLING TH E PU LLER
Thisfunction is only require d forthe crotch seam .
01 = Function on
00 = Function off
45 PU LLER AFTER HIPBOW
The section the pullerrem ains low ered afterDURATION OFLOW
SPEED AT HIP B O W (param eter22).
Pullerspeed as setin param eter14.
Flyroller
37UNTIL FLY R O LLER DO W N
R equire d forpreseam 3 fora betterguidance ofthe fly bow.
38DURATION OF FLY ROLLER DOW N
The timeforw hich the flyrollerislow ered.