Operation Manual
3.4Pullerand ejector
3.4.1 Changing the toothed beltofthe step m otor
Caution:Risk ofinjury!
Switch the m ainswitch off.
C hange the toothed beltonlywiththe sew ing unitsw itched off.
–
Low erthe feeding unitontothe tabletop m anually.
–
Switch the sew ing unitoff.
–
Screw offcoverplate1.
–
Screw outthe screw 2.
–
Loosen screw 4 and sw ivelcylinder3 tothe rear.
–
Loosen screw 6 and release the tension ofthe toothed belt5.
–
Rem ove the toothed beltfirs t fro m the drive roll7 and then fro m the
feed rollerofthe puller.
–
Fitthe new toothed beltin reverse order.
–
Tension toothed belt5 and tighten screw 6.
Ifthe tension is c o rre c t,itm ustbe possibleto bend the toothed
belt5 inthe m iddle by approx.5 m m w ith sensible counter
pressure.
–
Swivelthe cylinder3 tothe frontagain and screw iton the puller
with screw 2.
–
Tighten screw 4.
–
Screw coverplate 1 on again.
33
3
4321
765