Operation Manual
3.3 Program stop
Foran im m ediatestop in case ofoperating errors,needle breakage
etc.the safety system ofthe 1265/5provides the follow ing m easures:
–
Press program stop sw itch2atthe controlpanel.
The running operations are stopped im m ediately.
–
Turn m ainswitch 1 counte r-c lockw ise.
The sewing unitdrops outim m ediately;
allm ovem entsofthe sew ing unitstop im m ediately.
3.4 R estartafterprogram stop
Caution:Risk ofinjury!
Switch the m ainswitch off.
Clearthe faultonlywiththe sew ing unitsw itched off.
Onlyrestartthe sew ing unitafterthe faulthas been cleared.
–
Switch on m ainswitch1(turn inclockw ise dire c tion).
–
Unlock the program stop sw itch.
The contro l loads the m achine program .
The m ain screen appears inthe display ofthe controlpanel.
The sewing unitis ready foroperation again.
7
1
21
2