Operation Manual

Set-up
Operating manual 100-69 version 00.0 - 05/2013
71
6.6 Conncetion to the in-house vacuum unit
Note: In case there is no in-house vacuum unit available, the vacuum device hat
to be ordered in addition. The connection procedure is explained in the
supplementary instructions.
Fig. 58: Connection vacuum unit
The suction unit facilitates the precise feeding and positioning of the work-
piece on the work table (1).
1. Connect the hose of the in-house vacuum unit to the connection
valve (2).
Material damage!
When mounting the vacuum device (side-channel blower) it is abso-
lutely necessary to exchange the joint ring (3) (black) at the connec-
tion valve against a filter ring (white) (included in the accessories).
ATTENTION
཰ི
(1) - Working table
(2) - Connection vacuum unit
(3) - Seal ring