Operation Manual

10. Photocells for flap scanning
Caution: Risk of injury!
Switch the main switch off.
Adjust the reflected light barriers only with the sewing unit
switched off.
Standard and checking
The light spots 2 and 3 of the photocells 1 and 4 must shine on the
reflected foils of the main clamp.
The light spots must hit the reflected foil approx. 1.5-2mmfrom the
outside edge.
Check whether the light beam of the photocells shines on the
reflected foil.
Correction
Loosen the screws at the photocell.
Adjust the photocell.
Tighten the screws at the photocell.
Correction of left light barrier for breast welt pocket
As far as sewing units for breast welt pockets are concerned, the left
light barrier 4 is automatically set to the correct position by the cylinder
6 when selecting a breast welt program.
Select the breast welt program.
Position the breast welt.
Loosen screw 5.
Adjust the light barrier with the eccentric 7 to match the breast
welt.
Tighten screw 5.