Operation Manual

3.6 Flap clamp
3.6.1 Flap clamp position
Caution: Danger of injury!
Switch the main switch off.
Check and adjust the flap clamp only with the sewing unit switched off.
Standard and checking
The flap clamps 2 must have a distance of 5 mm parallel to the inside
of the main clamp 1.
Close the flap clamp manually.
Check the distance between flap clamp 2 and the inside of main
clamp 1.
Correction
Loosen the screws 4.
Shift the flap clamp holder 3 correspondingly.
Tighten the screws 4.
3
19
21 43
5mm