Operation Manual

05 Clamp automatically down
When a time is set, the main clamp will close after reaching the feeding
position plus the set time only.
Input: min = 0,0, max = 1,0
Factory setting: 0,0
06 Time after clamp down
Time delay between the function “clamp down” and the next operation.
Input: min = 0,0, max = 1,0
Factory setting: 0,3
07 Time before feeding
When the set time is over, the main clamp moves from the feeding
position to the sewing start (When the foot switch is pressed forwards)
Input: min = 0,0, max = 1,0
Factory setting: 0,2
08 Piping blowing on/off
The piping or the flap are blown against the folder to avoid “slipping” of
the piping.
When moving towards the needles, the blowing is automatically
effected at the seam beginning.
Input: 00: off
01: on
09 “Thread clamp open” at the seam beginning
After the first two stitches the needle threads should be released by
the thread clamp.
The thread clamp opens after the number of stitches set here.
Input: min = 0,0, max = 20
Factory setting: 2
10 “Thread clamp open” - Duration
Duration of “opening the thread clamp” at the seam beginning.
The thread catcher must extend so far that the threads are released.
Input: min = 0, max = 99
Factory setting: 20 ms
11 Until the needle thread is trimmed at the seam end
Time for catching and trimming the needle thread.
Input: min = 0, max = 100
Factory setting: 30
12 Duration of needle thread trimming
Duration of impulse for thread catcher
The cylinder must extend completely.
Input: min = 0, max = 50
Factory setting: 28
24