Operation Manual

4
21
29 Folding slide mode
Via this parameter the folding slide is set.
Input: 00: Left and right folding slide active
01: Left folding slide active
02: Right folding slide active
03: Left and right folding slide inactive
30 Vacuum mode (option)
In conjunction with icon under the menu “seam functions”
Via this parameter the activation of the vacumm is set.
Input: 00: Vacuum on automatically, main clamp
to the feeding position
01: Vacuum on by foot switch forwards
31 Main clamp mode
Via this parameter the activation of the main clamp is set.
Input 00: Left/right main clamp down with pressure
01: Left main clamp down with pressure
02: Right main clamp down with pressure
03: Both main clamps not fixed
32 Stacker mode
Input 02: Stacker
03: Stacker and ejector
When equipped with blower:
Input: 01
Reverse lock active inactive
Input: 00: Back push barrier active
01: Back push barrier inactive
34 Flap clamp mode, left
Input 00: Flap clamp active with foot switch only
01: Flap clamp active automatically
35 Flap clamp mode, right
Input: 00: Flap clamp active with foot switch only
01: Flap clamp active automatically
36 Breast welt mode
The following working methods are possible:
Input: 01: Folder down after flap clamp closed
02: Folder down after left main clamp closed